The best Side of Dp50rb
The best Side of Dp50rb
Blog Article
Find greater diagnostic facts by means of extended watch of the anatomical construction on all convex probes.
The DP-50 Expert is definitely an impressive, substantial-general performance Ultrasound Process engineered that may help you get the insights you would like. The Program’s powerful engine and substantial-velocity processing give superb picture excellent and a whole data administration Answer.
Click Concur and Continue to accept cookies and go straight to the positioning or click on More details to discover thorough descriptions of the types of cookies and pick out irrespective of whether to just accept particular cookies though on the positioning.
Take note: Make certain that you could possibly pull out and drive into the IO board sockets vertically when pulling out and assembling the IO board assembly on the place with the handle. Take away panhead screws with washers M3X6 (four) accustomed to protected the IO board, and then you may get out the IO board. Site 116 Get rid of panhead screws with washers (two M3X6) that happen to be mounted on the primary unit, acquire out the higher baffle and afterwards pull out two cables connecting the main board to the facility module assembly.
The chapter materials the tactic to validate main function and performance of item. This really is only employed for reference, not preventive execution. Operate checking and testing of the part shall be carried out by Mindray assistance engineers and the consumer with each other. Web site 66: Standard Test
three. Click the higher icon while in the monitor (prompts “Update” if you put the cursor on it), the update stage is performed, if fails, make sure you deliver to R&D Middle. Figure 6-1 Key Keep track of Routine maintenance Monitor 4. Following update is prosperous, restart the device immediately after ability off to make the info helpful. HDD Partition ... Web site ninety one structured report linked info file and DICOM viewing application Report report template obd.bin OBD info file version.txt Variation file Comment Remark file AnatomyImage Anatomical pictures Measurement Measurement library Doppler program and associated boot configuration key file and plug-ins, distant desktop server Multilanguage string file exe videoplay.
Overall performance Take a look at five.five.one Test Procedure Resolution Detection depth Geometric Place Accuracy Blackout region check Record the Test illustrations or photos 5.five.two Examination Articles The image employed Here's only for reference, stick with the graphic result in the actual Be aware: predicament. Necessities: Show: established the distinction and brightness in the scientific software benefit (or even the default standing) Procedure atmosphere: darkish room, simulating the clinical application atmosphere. Webpage seventy six In ailment which the transverse resolution screening targets are horizontally shown, file the minimum length of two targets that may be Evidently acknowledged. Repeat the operation previously mentioned for that transverse resolution testing targets at other depths. As revealed in figure down below. Axial resolution ... Site 77 When using the convex probe, maintain the transverse resolution screening targets to notice: be displayed near the midline. When utilizing a linear probe with steer perform, never turn on the steer operate when perform the transverse resolution examination. Zoom within the area where by the targets located if needed. The diameter of your target position at a particular depth is equivalent on the transverse resolution for the depth. Web site seventy eight five.
five.2.three Geometric positioning accuracy Longitudinal geometric positioning precision Take a look at Phase: Do adjustments as the way in tests the maximum depth. Record the space by 20mm Just about every segment on the longitudinal targets line utilizing the measurement caliper; Pick the worth with the greatest mistake (to 20mm), determine the precision utilizing the method beneath The measurement caliper ought to be positioned within the upper edge of the concentrate on, Notice:... Page seventy nine Transverse geometric positioning precision Examination Step: Protect the scan surface on the phantom with h2o or couple gel, gently Get hold of the probe With all the scan floor Adjust the depth, generating the transverse targets to generally be displayed inside the impression. Regulate the main target stage to get posited beside the transverse targets (the conventional isn't obvious) Modify parameters like achieve, TGC, generating Each individual transverse targets to be clearly exhibited. Web site eighty 5.five.two.4 Blackout Location Examination Phase: Go over the scan surface area from the phantom with h2o or few gel, gently Get in touch with the probe Using the scan area Change the depth in a decrease value, and set the main target at the nearest spot to the scan area. Lessen the value of parameters like AP, Get right up until the background sound just can be viewed. Website page eighty one: Application Upgrade And Dp50rb login Servicing
Greatest four times tasking for one transmitted beam, causing great time resolution and better frame rate.
After changing the CPU module, crucial file needs to be generated Once more based on the new MAC deal with and created into HDD of the device. Or else, the configuration function of the item might be shed. Immediately after removing the CPU module, Take away panhead screws with washers (twelve M3X6) set on the most crucial unit box, you might take from the board. Webpage 118 Figure eight-29 Disassemble the Control Panel Assembly (1) Keep the upper edge of control panel assembly, and open up up the control panel. Figure eight-thirty Disassemble the Control Panel Assembly (two) Immediately after taking away one countersunk head self-tapping screw PT3X10 fixed about the user interface and acquire out the plug on the keyboard and the key unit connecting cables, you could eliminate the control panel assembly.
Return into the technique preset interface. The option status alterations into Uninstalled. The uninstalling perform is distinctive to internal customers.
This handbook could referring to data secured by copyright or patents and does not convey any license underneath the patent rights or copyright of Mindray, or of Some others. Web site 9: Statement
A smart new form, Increased mobility and practical operation make DP-fifty well suited for all medical configurations.
Notice: On the watch, the brightness adjustment comes in advance of distinction. Soon after readjusting the watch’s distinction and brightness, alter all preset and peripheral options.